Part 145 Capability Lists: How to Build and Maintain One
If your repair station holds a limited rating, your capability list defines what you're allowed to work on. Get it right and adding new work is a straightforward internal process. Get it wrong and you can end up performing work outside your authority, or with an application that stalls. Here is how the capability list works under 14 CFR 145.215.
Who needs a capability list?
Under 145.215(a), a repair station with a limited rating may perform maintenance, preventive maintenance or alterations on an article if the article is listed on a current capability list acceptable to the FAA, or on the repair station's operations specifications. In practice, most shops with limited ratings use a capability list because it can be updated through their own manual procedures instead of an operations specifications change.
What goes on the list
The regulation requires the list to identify each article by make and model, or other nomenclature designated by the article's manufacturer, in a format acceptable to the FAA (145.215(b)). A clear list usually includes:
- The manufacturer and part number or model of each article
- A description of the article (for example, "starter generator" or "VHF transceiver")
- The rating it falls under
- The type of work performed (inspection, repair, overhaul, alteration)
- The technical data you use for that article, such as the component maintenance manual and its revision
Every article must fall within the scope of the ratings on your certificate. A capability list can't expand your ratings; it can only list specific articles within them.
The self-evaluation: the step most shops underestimate
Under 145.215(c), an article may be added only after the repair station performs a self-evaluation, following procedures in its Repair Station Manual, showing that it has all of the housing, facilities, equipment, material, technical data, processes and trained personnel in place to perform the work. The repair station must keep documentation of that evaluation on file.
A practical self-evaluation is a checklist for each new article that confirms:
- Current manufacturer technical data is on hand and controlled
- Every special tool and piece of test equipment the data calls for is available and calibrated
- Technicians and inspectors are trained on the article, and the training is recorded
- Housing and facilities are suitable (for example, clean-room, ESD or environmental requirements)
- Materials and parts can be sourced and inspected properly
- The work can be documented on your existing forms
The evaluation is signed by the person your manual designates and filed with the capability list revision.
What your Repair Station Manual must say
14 CFR 145.209(d) requires the RSM to include procedures for revising the capability list and notifying your responsible Flight Standards office of revisions, including how often the office will be notified, and procedures for the self-evaluation, including methods and frequency and how results are reported to the appropriate manager for review and action. When you add an article, 145.215(d) requires you to provide the office with a copy of the revised list in accordance with those procedures.
Common capability list problems
- Listing articles "for the future." Every listed article must be supported today, with data, tools and trained people.
- Missing self-evaluation records. If you can't produce the documented evaluation, the listing isn't supported.
- Outdated technical data. A list that references superseded manual revisions suggests your data control isn't working.
- Articles outside your ratings. Check every entry against the ratings on your certificate.
- No notification record. Keep proof of when and how revised lists were sent to the FAA.
Starting your first capability list
For a new applicant, the capability list is built alongside the RSM and QCM. Start with the articles you are equipped and trained to support on day one. A focused list is easier to defend in the FAA's review, and you can add articles after certification using your own self-evaluation procedure.
Need help?
AMC prepares capability lists and self-evaluation procedures as part of our certification packages, and can review an existing list during a gap analysis.